CYNDAR Sensor Manufacturer
Offering retail and bulk orders, reliable quality, and superior service
Products Description
| safety light curtain | safety light curtain | |||
| Mode | CCT 10-14-1262BB | |||
| Features | Number of Optical Axes | Beam Spacing | Protective Height | Scan range |
| Illustration |
|
|
|
|
| Features | 10 beams | 14mm | 126mm | 6m |
| Secure Outputs (OSSD) | 2 PNP NC | |||
| Interface Plug | M12 Connector | |||
| Package | 1 receiver and 1 transmitter, screw bracket accessories, 3-meter cable | |||
| synchronous | Line synchronization | |||
For more specifications, please refer to the user manual and contact customer service.
Xinda CYNDAR has launched lightweight optical monitoring products for narrow installation spaces and special structural equipment, improving overall operational standards without changing equipment layout. Gathering industry technical elites, continuously investing in the research and development of safety light curtains, building core competitiveness with patented technology, and leading the high-quality development of the industry.
More product descriptions
|
Product Name |
Safety Light Curtain |
|||||||
|
Relevant parameters |
||||||||
|
Light curtain form |
Firing method |
|||||||
|
Optical axis spacing |
10mm |
14mm |
20mm |
25mm |
30mm |
40mm |
80mm |
200mm |
|
Detection accuracy |
18mm |
22mm |
28mm |
33mm |
38mm |
48mm |
88mm |
208mm |
|
Number of light beams |
6,8...32 |
6,8...32 |
4,6...32 |
6,8...32 |
4,6...32 |
4,6...32 |
4,6...20 |
4,6...12 |
|
Protection height |
Optical axis spacing × (Number of beams - 1) |
|||||||
|
Detection distance |
0.3~3m(A);0.3~6m(B) |
|||||||
|
Electrical data |
||||||||
|
Power supply voltage |
DC12/24V |
|||||||
|
Consumption current |
≤200mA |
|||||||
|
Response time |
≤15ms |
|||||||
|
Output |
NPN/PNP type, with a current injection of 500mA, with a voltage drop of less than 1.5V, featuring polarity, short-circuit and overload protection. |
|||||||
|
Switching elements |
PNP crystal or/NPN transistor |
|||||||
|
Controller
|
Light curtain controller (AC110-220V relay output) | |||||||
|
Safety relay (DC24V relay output, dual channel, manual/automatic reset selectable) |
||||||||
|
Output state |
When all optical axes are illuminated, the receiver is ON (green light indicates this). |
|||||||
|
Indicator light |
Projector: Power indicator light (red); Receiver: Output indicator light is on (green) / blocked (red) |
|||||||
|
Mechanical data |
||||||||
|
wavelength |
805mn |
|||||||
|
Light source |
Modulated Infrared LED |
|||||||
|
Cross-sectional dimensions |
30mmx30mm |
|||||||
|
Shell material |
Aluminum alloy, end cover: ABS reinforced nylon. |
|||||||
|
Electrical Interfaces |
||||||||
|
Number of Interfaces |
2 (Transmitter and Receiver) |
|||||||
|
Interface Types |
7-pin, M12 connector |
|||||||
|
Environmental Data |
||||||||
|
Protection grade |
IP65 |
|||||||
|
Resistance to light interference |
10000lux(Incident angle ≥ 5°) |
|||||||
|
Resistance to ambient light |
Incandescent light: Light intensity on the receiving surface is 3000 lux; sunlight: Light intensity on the receiving surface is 10000 lux. |
|||||||
|
Ambient temperature |
Workshop: -10 - 40℃ (but not freezing), storage: -25 to 55℃ |
|||||||
|
Ambient humidity |
Workshop: 35 - 85% RH, storage: 35 - 95% RH |
|||||||
|
Packaging |
Standard industrial environment |
|||||||
|
Allowable cable length |
100m |
|||||||
Model Description
|
Example Model: CCT 08-40-280 2AA-5m Anti-interference Safety Light Curtain CCT: 8 beams, 40mm optical axis spacing, 280mm detection height, two sets of normally closed NPN outputs, 3m through-beam, 5m cable. |
|||||||
|
CCT |
08- |
40- |
280 |
2 |
A |
A |
-5m |
|
|
|
|
|
|
|
|
|
|
Product Series |
Number of beams |
Optical axis spacing |
Protection height |
Output quantity |
Output method |
Sensing distance |
Data cable length |
|
CCT |
04 06 08 ... 32 |
10:10mm 14:14mm 20:20mm 25:25mm 30:30mm 40:40mm 80:80mm 200:200mm |
Effective product height :Height = (Number of beams - 1) * Spacing |
2: Two sets of outputs |
A: NPN NC B: PNP NC C: NPN NO D: PNP NO |
A: 0.03-3M B: 0.03-6M |
Standard configuration: 3 meters (not specified) 4m: 4 meters 5m: 5 meters ... 30m: 30 meters |
Factory configuration
Controller optional
|
Model |
Name |
Specifications |
Output |
Description |
Picture | Wiring diagram |
|
LCBP1 |
Light curtain controller |
AC 110~220V |
1NC+1NO |
Suitable for a set of lightweight curtains (7 cores - PNP). |
|
Wiring diagram for light curtain and LCBP1 |
|
SRC106 |
Safety relay |
DC 24V |
3NC+1NO |
Dual-channel, manual/automatic reset selectable(7 cores - PNP). |
|
Wiring diagram for light curtain and SRC106 |
Accessories Specifications
|
Name |
Picture |
Dimensions |
Application |
|
T-type screw |
|
|
|
|
CA02/Standard configuration |
For side groove installation method |
||
|
Right-angle bracket |
|
|
|
|
CA04/Standard configuration |
For CCT end mounting method |
||
|
Convex nut |
|
|
|
|
CA03/Optional |
For side groove installation method |
||
|
Stainless steel pipe support |
|
|
|
|
CA01/Optional |
For tubular installation method |
Light curtain wiring diagram
| PNP Wiring Diagram | NPN wiring diagram |
|
|
|
| ►For further questions, please contact customer service or check out the technical support section. |
Hot Tags: anti-interference safety light curtain | cct 10-14-126 2bb cyndar, China, manufacturers, factory, buy, price, cheap, Automation Light Curtain Safety System, Highly sensitive safety edge for machine edge, light curtain machine guarding, light curtain type 2, Mini sensing edge, Safety edge for machine safety equipment